Insulation Calculator

Subtract the R-value you have from the target, then divide by the product's R-value per inch. Going from R-11 to R-49 with insulation rated R-3.2 per inch takes 38 ÷ 3.2 = 11.9 in of new insulation.

Updated

Your measurements

Units
R
R
R per in

Use the figure on the bag or batt label.

sq ft

Results

Thickness to add
–
R-value to add
–
Insulation volume
–

Results update as you type.

How to use the insulation calculator

  1. Enter the R-value you have now. Measure the depth of existing insulation and multiply by its R-value per inch, or use 0 for an uninsulated space.
  2. Enter the target R-value (see the ENERGY STAR table below).
  3. Enter the R-value per inch of the product you will install, from the bag or batt label.
  4. Optionally enter the area to see the volume of insulation.

Check the R-value already in place before you buy, because you only need to add the difference; Decoratoradvice takes your current level into account.

Insulation formula

R-value to add = target R − current R

Thickness = R-value to add ÷ R-value per inch

Volume = area × thickness

Worked example

An attic with R-11 now, a target of R-49, and loose-fill rated R-3.2 per inch:

R to add: 49 − 11 = 38

Thickness: 38 ÷ 3.2 = 11.9 in

For 1,000 sq ft: 1,000 × 11.875 ÷ 12 = 990 cu ft

ENERGY STAR's recommendations, based on the 2021 International Energy Conservation Code:

Climate zoneAttic, uninsulatedAttic with 3–4 in existingFloor
1R30R25R13
2R49R38R13
3R49R38R19
4A and 4BR60R49R19
4C, 5 and 6R60R49R30
7 and 8R60R49R38

The "existing 3–4 in" column is the R-value to add on top of what is there.

Walls

Wall cavities limit thickness. The U.S. Department of Energy notes that 2 × 4 walls can hold R-13 or R-15 batts and 2 × 6 walls R-19 or R-21 products. Adding more R-value to walls usually means insulated sheathing outside the studs. The stud calculator covers framing.

Tips

  • Seal air leaks into the attic before adding insulation.
  • Keep insulation clear of soffit vents with baffles so the attic still breathes; the attic ventilation calculator works out the vent area.
  • Loose-fill bags list coverage by R-value; use that chart to count bags once you know the depth.
  • See how long the upgrade takes to pay back with the energy upgrade payback calculator.

Common mistakes

  • Using a generic R-per-inch figure. Products differ; use the one on your label.
  • Compressing batts. Squashing insulation into a smaller space lowers its R-value.
  • Covering vents or recessed lights not rated for contact with insulation.

Frequently asked questions

How many inches of insulation do I need for R-49?

It depends on the product. At R-3.2 per inch, about 15.3 in from zero; check your product's label.

What R-value should my attic have?

ENERGY STAR recommends R30 to R60 for uninsulated attics depending on climate zone; see the table above.

What is R-value per inch?

How much thermal resistance each inch of the product provides. Manufacturers must provide R-value information under the FTC's R-value Rule.

How do I convert metric RSI to R-value?

Multiply RSI by 5.678. RSI 8.6 is about R-49.

Does insulation help my air conditioner?

Less heat gain means a smaller cooling load. Size room units with the BTU calculator and ducts with the duct size calculator.

Key takeaways

  • Thickness = (target R − current R) ÷ R per inch.
  • Use the R-value per inch from your product's label.
  • ENERGY STAR recommends attic levels from R30 to R60 by climate zone.
  • Seal air leaks first and keep soffit vents clear.